Product Description
Professional air handling unit solution for clean rooms, rooftops, and cooling systems with over 17 years of technical expertise.
Clean Operating Room Air Conditioning System
According to clean operating room design specifications, this system maintains constant temperature, humidity, fresh air treatment, and air purification. It ensures positive and negative pressure differences to control bacteria concentration and reduce infection risks. Functions include air purification, transportation, cooling, dehumidification, humidification, heating, and intelligent control.
Solution 1: DC Frequency Conversion System
DC Frequency Conversion Outdoor Unit + Clean Operating Room AHU + PLC Intelligent Control
- Frequency Conversion: DC frequency conversion compressor adjusts frequency based on temperature for high efficiency.
- Low Ambient Cooling: Outdoor unit adopts EC fan with condensing pressure sensor for -20ºC low-temperature operation.
- Low Temperature Air Supply: Unique technology achieves a minimum air supply temperature of 5ºC via evaporator grading.
- Precise Control: Electric reheating and preheating adjusted by SCR for accurate indoor temperature.
- Low Temperature Heating: Advanced air jet enthalpy technology enables normal heating at -20°C.
Solution 2: Four-Pipe Heat Recovery System
Four-pipe Air-cooled Heat Pump Unit + Combined Air Conditioner + PLC Control
- Multi-function: Realizes simultaneous cooling and heating energy recovery without extra water tanks.
- High Efficiency: Cooling Energy Efficiency Ratio (EER) ≥ 4.0; combined efficiency ≥ 9.0.
- System Stability: Single four-way valve design ensures reliable operation and mature technology.
- Self-Diagnosis: PLC technology detects suction/exhaust pressure, temperature, and overload faults automatically.
Solution 3: Air-cooled Heat Pump System
Air-cooled Heat Pump + Combined Air Conditioning Unit + PLC Control
- Smart Defrosting: Super-cooling ice suppression technology combined with unique defrosting modules.
- Cloud Service: Real-time monitoring available via PC client and mobile application.
- Operating Stability: DC inverter compressor matches power to ambient temperature changes.
Frequently Asked Questions
1. What applications is the AHU-02 best suited for?
The AHU-02 is specifically designed for medical environments, including clean operating rooms and pharmaceutical clean rooms that require strict temperature and humidity control.
2. Can the system operate in extremely cold climates?
Yes, the unit features advanced air jet enthalpy technology and low-temperature refrigeration design, allowing it to provide stable cooling and heating even at ambient temperatures as low as -20°C.
3. How energy efficient are these air handling units?
By utilizing DC frequency conversion and energy recovery technology (Solution 2), the system can achieve a combined cooling and heating energy efficiency ratio of up to 9.0.
4. What is the expected lifespan of the AHU-02?
The unit is built with high-quality galvanized sheets and ultrahigh corrosion durability materials, ensuring a service life of more than 20 years with proper maintenance.
5. Does the unit support remote monitoring?
Yes, the system is equipped with smart cloud services that allow for real-time monitoring and management via PC clients and mobile applications.
6. How does the system ensure clean air in surgical rooms?
It integrates multi-stage air purification, precise pressure difference control, and specialized fresh air treatment to meet clean operating room design standards and reduce infection risks.